Skip to content

Home / Gear Guides / Regulators

Buying guide

Choosing a regulator and pressure gauge.

A regulator is the piece of life-support equipment a diver breathes from. Your training and your instructor come first, and servicing is for trained technicians. This guide explains what the markings on a regulator mean according to the bodies that define them, so you can read a specification. For how a regulator works, see regulators.

Disclosure: this page has affiliate links. If you buy through them, we may earn a commission at no extra cost to you. As an Amazon Associate we earn from qualifying purchases. How this works.

How we recommend

We recommend gear by category and use, not by brand, and do not quote prices. We may earn a commission on purchases at no cost to you.

Get trained

This page explains what training agencies, standards bodies and diving medicine bodies publish. It is not a substitute for training and certification from a recognised agency, and it does not replace medical advice.

Training and servicing come first

How to assemble, check and breathe from a regulator, and what to do if something goes wrong, is taught by your instructor on a course. Nothing here replaces that, and we never say a regulator is safe or certified.

Servicing is for trained technicians. PADI (2015) says a regulator with an internal problem should go to a certified technician and should not be taken apart without training. DAN Europe (Guy Thomas, 2022) says makers usually require changes and servicing to be done by authorised dealers or trained technicians using approved parts and lubricants, and that non-original parts may void the CE marking and the warranty. A UK dive dealer's 2023 summary reports that many warranties depend on regular authorised servicing.

What the EN 250 markings mean

The European standard is EN 250:2014, "Respiratory equipment, Open-circuit self-contained compressed air diving apparatus, Requirements, testing and marking". Its scope sets minimum requirements for open-circuit compressed-air scuba and its sub-assemblies, aiming at a minimum level of safe operation to a maximum depth of 50 m. DAN Europe (2022) explains the markings you may see in a specification:

MarkingWhat DAN Europe (2022) says it means
EN250A first stage with one second stage, tested to 50 m and in water as cold as 4 C, covering work of breathing and resistance to freezing.
EN250 >10 CApproved only for water warmer than 10 C.
EN250AThe first stage was also tested supplying two second stages, for two divers at once, and is approved to 4 C. Two-diver use is tested only to 30 m.
EN250A >10 CAs EN250A, but limited to water warmer than 10 C.

In other words, by DAN Europe's account a regulator carrying the ">10 C" limit is not approved for water at 10 C or colder. DAN Europe also stresses that a CE marking confirms only that minimum requirements were met; real performance still varies with design, temperature and depth.

An older maker manual frames it differently. Mares' manual for its REBEL regulator, from the EN 250:2000 era, says that edition treated water below 10 C as cold, that its regulators needed a factory cold-water kit fitted only by an authorised service centre for cold-water use, and that EN 250 equipment was not intended for more than one user breathing at once. DAN Europe's 2022 account describes the A marking as a tested two-diver approval to 30 m. The difference may come from the 2000 and 2014 editions, but our research could not confirm that, so the manual for a given regulator is the reference for it.

Our picks by category

PICK 1

Regulators

DAN's Alert Diver (2012) describes a regulator as a first stage on the cylinder valve, an intermediate-pressure hose and a second stage in the mouth, delivering gas only when the diver inhales. DAN says an unbalanced first stage's intermediate pressure can drift as the cylinder empties or depth changes, which can make breathing harder, while a balanced first stage keeps it steadier, and balanced second stages reduce the effort needed to start each breath. By DAN Europe's account, the EN 250 marking shows the water temperatures a regulator was approved for. First-stage fittings also differ: Mares' manual, for example, lists its first stages with a DIN 477/50 screw fitting rated to 300 bar or an international yoke (CGA 850) rated to 232 bar (maker statement).

Best for: Certified divers ready to own their breathing gear

PICK 2

Pressure gauges and consoles

PADI says a submersible pressure gauge (SPG) shows how much gas is left in the cylinder. It can be a hose-connected mechanical gauge reading in bar or psi, or built into a dive computer, and a console combines the SPG, a computer or depth gauge and a compass. With hoseless air integration, PADI says, a transmitter on the first stage sends cylinder pressure to the computer wirelessly. PADI also says an SPG should be secured so it does not dangle, add drag, strike marine life or get damaged.

Best for: Divers whose regulator has no gauge or computer

The alternate air source

A spare second stage carried as an alternate air source has a nickname. Scuba Diving magazine, in a page we could see only as a search summary and could not confirm, says it is commonly called the "octopus", is usually yellow so it stands out, and that its performance depends on the first stage being able to supply two second stages and a BCD inflator at once. DAN Europe (2022) warns that changing or adding a second stage, octopus or hose can alter how the whole regulator performs, even when every part is CE-marked, and says makers publish lists of approved combinations.

Nitrox

A regulator for enriched air nitrox is a separate question, and agencies train divers in nitrox use, as a separate course or, at BSAC, within the Ocean Diver course; see specialty certifications. The European standard EN 13949:2003 covers open-circuit scuba for nitrox with more than 22 percent oxygen, or oxygen, and adds requirements and tests on top of EN 250. The bodies set different oxygen thresholds for treating equipment as oxygen service:

  • 22 percent: the scope of EN 13949:2003.
  • 23.5 percent: DAN's equipment workshop page, citing regulatory codes and safety standards, and Luxfer's requirement for its cylinders.
  • 25 percent: DAN's Alert Diver (Francois Burman, 2022), at typical cylinder pressures.
  • 40 percent: SDI (2012) for cylinders and valves, and the Mares REBEL manual for its regulators outside Europe only (maker statement).

DAN (2022) says only properly trained, competent technicians should perform oxygen cleaning. The maker's manual and the technician decide whether a given regulator can be used with nitrox. See nitrox equipment.

Service intervals

Each maker sets its own interval. Mares' REBEL manual (maker statement) calls for inspection at an authorised Mares service centre at least once a year and replacement of the first-stage valve every two years or every 200 diving hours. A UK dive dealer's 2023 summary reports maker recommendations: Scubapro, a full overhaul every two years, or yearly with heavy use of about 100 or more dives; Mares, inspection yearly or every 100 dives and overhaul every two years or 200 dives; Aqualung, yearly inspection and a two-year overhaul; Apeks, an overhaul at least yearly regardless of use. We could not check the dealer's figures against each maker, and the two Mares figures disagree (200 diving hours in the manual, 200 dives in the dealer summary). The interval that applies is the one in your regulator's own manual.

Care

PADI (2015) says sand can lodge in regulators and salt water corrodes metal, so gear should be rinsed in fresh water after each dive, and that hoses should be coiled loosely in storage to avoid kinks. Published advice on how to rinse a regulator conflicts, as set out on care and storage.

Keep reading

Disclosure TheGearSports Scuba Diving is reader-supported. When you buy through links on our site, we may earn an affiliate commission at no extra cost to you. As an Amazon Associate we earn from qualifying purchases. Our recommendations are independent.